Student guide
The unit has ASA software release 9.9(2)85 and the Security Plus licence. It has ASDM 7.16(1). It has a FirePOWER module with software release 6.2.3. The module is not configured. The unit is at the factory default configuration.
This guide covers access only. It does not cover configuration.
Console
- Connect the console cable to the RJ45 console port. You can also use the mini-USB port.
- Set the terminal to 9600 baud, 8 data bits, no parity, 1 stop bit.
- Press Enter. The prompt shows
ciscoasa>. - Enter
enable. The factory default configuration has no enable password. - Enter
show version | include Serial. The command shows the licensing serial number.
A console that stops at Lina to use serial port /dev/ttyS0 for console IO has the
known fault. Tell the operator. You cannot repair this fault from the console.
ASDM
- Connect your computer to an inside port. Use a port from Gi1/2 to Gi1/8.
- Make sure that your computer has a DHCP address.
- Open
https://192.168.1.1/admin. - Accept the self-signed certificate.
- Log in with an empty user name and an empty password.
ASDM needs Java 8 with Web Start. Adoptium/Temurin 8 does not include javaws. Use
Oracle JRE 8. You can also start the launcher JAR files directly.
FirePOWER module
- Enter
session sfr consoleat the ASA console. - Log in with the user name
adminand the passwordAdmin123. - Enter
setup. The wizard configures the module management network. - Press Ctrl-Shift-6. Then press
xto return to the ASA console.
Power off
The preferred procedure is to start ROMMON and then disconnect the power supply. In ROMMON, the unit does not write to the storage. The module does not operate.
- Enter
reload. - Press ESC at the boot prompt.
- Disconnect the power supply.
The unit has no power switch. The module starts when you connect the power supply again.